1. Product function:
1. With multiple alarm detections: touch screen alarm, bypass alarm (anti-short circuit), short circuit alarm, disconnection alarm, switch input alarm, equipment failure self-detection (touch screen alarm, bypass alarm, these two functions are Optional function, other functions are conventional alarm functions).
2. The conventional communication interface is RS485 interface and standard switch interface (for network transmission, a dedicated network module needs to be added separately).
3. Diversified alarm output interfaces: DC12V and switch interface (normally open/normally closed dry contact). The DC12V alarm output port can directly drive two 12V alarm devices; the switch output can be used with various brands of alarm hosts and modules.
4. "Pulse amplitude" can be directly modified through the host control panel, and can be adjusted from 0.7kv to 5.0kv.
5. "Auto/Manual Mode" can be modified directly through the host control panel.
2. Product technical parameters:
1. Peak output voltage: 5KV~10KV
2. Peak output low voltage: 700~1000V
3. Peak output power: <10A
4. Pulse width (pulse duration): ≤0.1s
5. Pulse interval time: 1s~1.5s
6. Pulse output power: 2.5mC
7. Pulse output energy: ≤5.0J
8. System power consumption: 15W